OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

Overview

The OPTIBAR OP 1110 is an orifice plate (OP) with ring-type joint (RTJ) design. The DP flow element is particularly suitable for high pressure applications with clean liquids, gases and low velocity steam flow. The RTJ orifice plate features an octagonal integral gasket for mounting between ring-type joint flanges.

The cross-section profile of the OPTIBAR OP 1110 is designed to fit inside the recess of the RTJ flanges and is used as flange sealing. The octagonal RTJ gaskets are made of a softer steel than the main material. In this way, the orifice is sealed reliably and stays clean when tightened with bolts. The OPTIBAR OP 1110 is available with a sharp edge on the upstream side and 45° edge on the downstream side or with bi-directional cross section profile.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Cost-effective DP flow element according to EN ISO 5167
  • Sizing: EN ISO 5167, ASME MFC-3M, AGA 3, ASME PTC 19.5 2004, GOST 8.586, RD 50-411-83
  • Easy handling and simple installation
  • Lowest uncertainty of discharge coefficient
  • High Reynolds number permissible according to norm
  • With optional vent drain holes

Related products

Compact orifice plate flowmeter

Integral DP flowmeter for liquids, gases and steam

  • Fast and easy installation without additional engineering, impulse lines and supports
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Line size: DN50…600 / 2…24"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

Integral orifice meter run assembly

DP flowmeter for process applications with small line sizes (down to DN15 / ½")

  • Standardised calibrated meter run assembly, designed acc. to ISO 5167 or ISO TR 15377
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Flange: DN15…100 / ½...4"
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 3050

Differential pressure transmitter for general flow, level and differential pressure applications

  • The most compact design in its class
  • Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
  • Reference accuracy ± 0.1%
  • 2-wire, 4…20 mA/HART®7

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 700 bar / 10,153 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®
Email